AC problems · Won’t turn on
AC not turning on? Start with these three checks.
A system that is completely dead is often a control problem rather than a broken machine: a thermostat, a breaker or a safety switch doing exactly what it was designed to do.
Or call (512) 692-7191 · Mon–Fri 7 AM–4 PM
- Flat price before work
- Same-day visits when the schedule allows
- Licensed & insured
Reset a breaker once only
Controls traced step by step
Do these first
Three checks that fix a surprising number of calls
-
1
The thermostat
Is the screen on? Replace the batteries. Confirm it is set to Cool with the temperature below the room reading. A blank screen can also mean the system has no power.
-
2
Both breakers
There are usually two: one for the indoor unit and one for the outdoor unit. Flip a tripped breaker fully off, then on. If it trips again, leave it off.
-
3
The drain safety switch
If the condensate drain is clogged, a float switch cuts the system off before water overflows. Look for standing water in the pan under the indoor unit.
If a breaker trips twice, stop
A breaker that trips again right after a reset is protecting the wiring from a short or a failing compressor. Resetting it over and over can turn a repairable part into a ruined one, and it is a fire risk. Leave it off and call (512) 692-7191.
Diagnosis
Why an AC will not start, most likely first
-
1
Thermostat batteries, settings or wiring
Dead batteries, the wrong mode, or a loose low-voltage wire. The simplest cause and the first thing to rule out.
-
2
Tripped breaker
Storms and power blips trip AC breakers. One reset is fine. A second trip is a fault that needs testing.
-
3
Clogged drain tripping the float switch
Very common in Austin’s humidity. Algae blocks the drain line, water rises in the pan, and the switch shuts the system down to save your ceiling.
AC leaking water -
4
Failed capacitor
The outdoor unit clicks or hums but never gets going. The start-and-run capacitor has failed.
Capacitor replacement -
5
Burned or stuck contactor
The switch that powers the outdoor unit wears out. In Texas, fire ants are drawn to it and can jam the contacts.
-
6
Blown low-voltage fuse
A small fuse on the control board blows when thermostat wires short, often after a new thermostat is installed or a trimmer nicks the wire outside.
-
7
Outdoor disconnect or its fuses
The pull-out switch beside the outdoor unit is out, loose, or has a blown fuse.
-
8
Transformer, control board or compressor
The less common and more involved failures. They are confirmed by testing, never assumed.
Compressor repair
What it costs
Typical cost by cause
| Cause | Typical Austin range | Notes |
|---|---|---|
| Thermostat batteries or settings | $0–$10 | Often solved on the phone. |
| Condensate drain cleared | $100–$300 | Includes testing the float switch. |
| Capacitor | $150–$400 | Usually fixed in a single visit. |
| Contactor | $150–$400 | Often replaced along with a capacitor. |
| Thermostat replacement | $150–$500 | Basic through smart models, installed. |
| Control board | $300–$800 | Brand-specific boards cost more. |
Market ranges for the Austin area, not a quote. See the full AC repair cost guide.
Questions
Asked often, answered straight
Something else on your mind? Call (512) 692-7191 and ask the technician directly.
Why did my AC suddenly stop working?
Most sudden shutdowns are a tripped breaker, a clogged drain that tripped the float switch, a failed capacitor, or a thermostat with dead batteries. Check the thermostat and the breakers first, then look for water in the drain pan.
Why is my thermostat blank?
Dead batteries are the usual reason. If new batteries do not help, the thermostat may be powered by the system, and a tripped breaker, a blown control fuse or a tripped float switch has cut that power.
Where is the reset button on an AC unit?
Most home air conditioners do not have one. The closest thing is switching the breaker off for five minutes and back on. If the system still will not start, something has failed and resetting will not fix it.
Why is the inside unit running but not the outside unit?
The thermostat is calling, but the outdoor unit is not responding. The usual causes are a tripped outdoor breaker, a failed capacitor or contactor, or a blown fuse in the disconnect. Switch cooling off so the indoor fan does not just circulate warm air.
Why won’t my AC turn on after I replaced the thermostat?
Usually a wiring issue: no common wire for a thermostat that needs one, wires on the wrong terminals, or a small fuse on the control board that blew when two wires touched. It is normally a quick fix.
Ready when you are
Talk to the technician, not a call center.
Leave your number and get a call back during business hours, or call now. You hear the likely cause, the timing and how pricing works before anyone rolls a truck.